Real-time Controllers for Power Apparatus Lab
Filter implementation: Nth order IIR filter implementation, time constant relationship with sam- pling times, Nth order FIR filter implementation, memory requirements for filters, Sapling and quantization errors, outputs for different input signals.
Controllers (simulated plant): Implementation of a P controller, implementation of an I control- ler,implementation of a PI controller, implementation of a 2 DOF controller.